A garsas lygis metras, taip pat žinoma as a triukšmas metras, is a fundamentalus instrumentas in triukšmas matavimas. A garsas lygis metras paprastai susideda of a talpioji mikrofonas, preamplifier, stiprintuvas, dažnis svoris tinklas, ir efektyvus vertė indikatorius galva. Darbas principas a garsas lygis metras is tas garsas is konvertuotas į an elektrinis signalas pagal a mikrofonas, ir tada varža is pakeista pagal a preamplifier to match the microphone with the attenuator. The amplifier adds the output signal to the weighting network, performs frequency weighting (or external filtering) on the signal, and then amplifies the signal to a certain amplitude through attenuators and amplifiers. It is sent to the effective value detector (or external level recorder) and provide the value of the noise level on the indicator head.

The frequency weighting network in the sound level meter includes A B. C Three standard weighting networks. The A network simulates the response of the human ear to a 40 square meter pure tone in the equivalent response curve, and its curve shape is opposite to the 340 square meter equivalent response curve, resulting in significant attenuation in the middle and low frequency bands of the electrical signal. The B network simulates the response of the human ear to 70 square pure tones, causing a certain attenuation in the low frequency range of electrical signals. The C network simulates the response of the human ear to 100 square meters of pure tones, with an almost flat response throughout the entire audio frequency range. The sound pressure level measured by the sound level meter through a frequency weighting network is called the sound level, and depending on the weighting network used, it is called the A sound level B and C sound levels, expressed in dB (A) DB (B) and dB (C).


At dabar, garsas lygis metrai naudotas for matavimas triukšmas gali būti padalintas į keturi tipai pagrįstas on jautrumas:


(1) Lėtas. Laikas konstanta of the meter head is 1000 ms, kuris is paprastai naudojamas to matas pastovi-būsena triukšmas, ir išmatuota vertė is the efektyvu vertė.


(2) Greitas. Laikas konstanta of the meter header is 125ms, which is paprastai naudojamas to matas nestabilus triukšmas su dideliais svyravimais ir transportas triukšmas. Greitas pavara priartėjimai the žmogus ausis's atsakas į garsą.


(3) Pulse or pulse hold. The rise time of the watch needle is 35ms, which is used to measure pulse noise with a longer duration, such as punching machines, press hammers, etc. The measured value is the maximum effective value.


(4) Pikas priežiūra. The rise time of the watch needle is less than 20ms. It is used to measure pulse sounds with a short duration, such as guns, cannons, and explosions. The measured value is the peak value, which is the maximum value.


The sound level meter can be connected to external filters and recorders for spectral analysis of noise. The domestically produced ND2 precision sound level meter is equipped with an octave range filter, which is easy to carry to the field and perform spectral analysis. Sound level meters can be divided into precision sound level meters and ordinary sound level meters based on accuracy. The measurement error of a precision sound level meter is about 1dB, while that of a regular sound level meter is about 3dB. Sound level meters can be divided into two categories according to their purpose: one is used to measure steady-state noise, and the other is used to measure unstable noise and pulse noise. An integral sound level meter is used to measure the equivalent sound level of unstable noise over a period of time. A noise dosimeter is also an integral sound level meter, mainly used to measure noise exposure levels. Pulse sound level meter is used to measure pulse noise, which conforms to the response of the human ear to pulse sound and the average time of the human ear's response to pulse sound.

 